大规模风火电源打捆的特高压交直流混联外送系统运行特性分析Analysis on Operation Characteristics of Large-Scale Wind-Thermal-Bundled UHV AC-DC Hybrid External Transmission System
郑博文,杨朋威,任正,王新宇,窦宇宇,王俊芳,陈财福
ZHENG Bowen,YANG Pengwei,REN Zheng,WANG Xinyu,DOU Yuyu,WANG Junfang,CHEN Caifu
摘要(Abstract):
针对新能源弱惯量、出力波动大、无功支撑能力差,严重影响弱同步支撑的送端电网暂态稳定特性及安全稳定运行的问题,采用PSASP(Power System Analysis Software Package)分析工具,以锡林浩特地区特高压交直流输电工程送端电网为对象,研究了大规模风电集中接入后,交直流系统与风火电源的交互作用以及系统暂态稳定性。搭建了典型风火电源打捆的交直流混联外送系统模型,对不同风电出力占比情况下系统发生交流短路故障、直流双极闭锁故障时的暂态稳定性进行仿真分析,得出了风电出力占比的提高将削减火电机组注入系统的暂态加速能量,提高系统暂态功角稳定性的结论。
In view of the characteristics of new energy, such as weak inertia, large output fluctuation and poor reactive power support capacity, which seriously affect the transient stability characteristics and the safe and stable operation of the sending end power grid with weak synchronous support, this paper uses PSASP(power system analysis software package)analysis tool and takes the sending end power grid of Xilinhot UHV AC/DC transmission project as the research object, the model of typical wind and thermal power bundled AC/DC hybrid external transmission system is built, the interaction between AC/DC system and wind-thermal power supply and the analysis method of system transient stability after large-scale wind power centralized access are deeply studied, and the transient stability of the system under AC short-circuit fault and DC bipolar locking under different proportion of wind turbine power is simulated and analyzed. It is concluded that the increase of the proportion of wind turbines power will greatly reduce the transient acceleration energy injected into the system and improve the transient power angle stability of the system, which plays a guiding role in reasonably arranging the operation mode of power grid and promoting the consumption of clean energy.
关键词(KeyWords):
风火电源打捆;特高压;功角稳定;直流闭锁;输电能力;新能源;消纳
wind-thermal-bundled;UHV;power angle stability;DC blocking;transmission capacity;new energy;consumption
基金项目(Foundation): 国网内蒙古东部电力有限公司科技项目“提升特高压直流输电能力的运行控制技术研究”(526604210004)
作者(Author):
郑博文,杨朋威,任正,王新宇,窦宇宇,王俊芳,陈财福
ZHENG Bowen,YANG Pengwei,REN Zheng,WANG Xinyu,DOU Yuyu,WANG Junfang,CHEN Caifu
参考文献(References):
- [1]朱子琪,张文松,李洛,等.考虑弃风限电风险的风火打捆外送多目标优化调度方法[J].可再生能源,2019,37(7):1034-1041.ZHU Ziqi, ZHANG Wensong, LI Luo, et al. Multi-objective optimization scheduling method for wind-thermalbundled transmitted considering wind curtailment and power shortage risk[J]. Renewable Energy Resources,2019, 37(7):1034-1041.
- [2]杨尉薇,朱玲,李威,等.风火打捆直流送出系统次同步振荡及传播特性研究[J].电力系统保护与控制,2019,47(20):58-64.YANG Weiwei, ZHU Ling, LI Wei, et al. Study on subsynchronous oscillation and propagation characteristics of wind-fire bundled sending system[J]. Power System Protection and Control, 2019, 47(20):58-64.
- [3]张海波,张琳雅,蒋维勇.风火打捆直流外送系统中极限风电渗透率的计算方法[J].电力系统自动化,2019,43(16):52-57.ZHANG Haibo, ZHANG linya, JIANG Weiyong. Calculation method for maximum penetration ratio of wind power in wind-thermal-bundled HVDC sending system[J]. Automation of Electric Power Systems, 2019, 43(16):52-57.
- [4]米合丽班·阿不都哈力里,王维庆,海云.基于D-PMSG的风火打捆直流外送系统送端功角暂态稳定性研究[J].电测与仪表,2018,55(21):75-79,92.Micheliban A. K., WANG Weiqing, HAI Yun. Study on sending-end angle transient stability for wind-thermal-bundled power based on D-PMSG transmission by DC system[J]. Electrical Measurement&Instrumentation,2018, 55(21):75-79, 92.
- [5]刘瑞宽,陈磊,闵勇,等.风火打捆送出系统动态安全域边界线性近似方法[J].电网技术,2018,42(10):3211-3218.LIU Ruikuan, CHEN Lei, MIN Yong, et al. A linear approximation method of dynamic security region of wind-thermal-bundled sending system[J]. Power System Technology, 2018, 42(10):3211-3218.
- [6]陈汉雄.直流功率转移对川渝弱交流电网安全稳定影响分析[J].电网技术,2018,42(12):4145-4152.CHEN Hanxiong. Analysis and study on DC power transfer and impact on sichuan-chongqing grid weak AC system security and stability weak AC system security and stability[J]. Power System Technology, 2018,42(12):4145-4152.
- [7]赵晋泉,朱尧靓,潘尔生,等.适用于大规模新能源接入直流送端电网的暂态压升严重性指标研究[J].南方电网技术,2020,14(12):1-9.ZHAO Jinquan, ZHU Yaoliang, PAN Ersheng, et al.Study on transient voltage rise severity index for the high renewable power-penetrated UHVDC sending-end power grid[J]. Southern Power System Technology,2020, 14(12):1-9.
- [8]郑超,马世英,申旭辉,等.强直弱交的定义、内涵与形式及其应对措施[J].电网技术,2017,41(8):2491-2498.ZHENG Chao, MA Shiying, SHEN Xuhui, et al. Definition, connotation and form of strong HVDC and weak AC and countermeasures for stable operation of hybrid power grid[J]. Power System Technology, 2017, 41(8):2491-2498.
- [9]陈嘉梁,严正,徐潇源,等.大规模新能源接入背景下小干扰稳定分析中状态矩阵特征值的灵敏度分析[J].南方电网技术,2020,14(2):55-61.CHEN Jialiang, YAN Zheng, XU Xiaoyuan, et al. Sensitivity analysis of eigenvalue of status matrix in smallsignal stability analysis considering large-scale renewable energy integration[J]. Southern Power System Technology, 2020, 14(2):55-61.
- [10]霍超,李兆伟,柯贤波,等.应对UHVDC送端电网新能源大规模脱网的频率紧急控制[J].电力工程技术,2020,39(4):42-47,60.HUO Chao, LI Zhaowei, KE Xianbo, et al. Emergency frequency control for large-scale disconnection of renewable energy in the UHVDC sending grid[J]. Electric Power Engineering Technology, 2020, 39(4):42-47, 60.
- [11]罗晨曦,徐政,陆韶琦.连接弱同步支撑系统的电压源换流器优化矢量控制策略[J].电力系统自动化,2018,42(23):14-19.LUO Chenxi, XU Zheng, LU Shaoqi. Optimized vector control strategy of voltage source converter linked to weakly-synchronized support systems[J]. Automation of Electric Power Systems, 2018, 42(23):14-19.
- [12]曹斌,王立强,赵永飞,等.基于PSCAD/EMTDC的大规模新能源并网电磁暂态并行仿真[J].中国电力,2020,53(11):154-161.CAO Bin, WANG Liqiang, ZHAO Yongfei, et al. Electromagnetic transient parallel simulation of large-scale new energy grid connection based on PSCAD/EMTDC[J]. Electric Power, 2020, 53(11):154-161.
- [13]印月,刘天琪,丁理杰,等.换相失败下弱送端系统安全稳定风险评估[J].电网技术,2020,44(6):2177-2186.YIN Yue, LIU Tianqi, DING Lijie, et al. Security and stability analysis method for weak sending-end system under commutation failure based on improved risk assessment[J]. Power System Technology, 2020, 44(6):2177-2186.
- [14]邵宝珠,张文朝,李家珏,等.基于短路容量的大规模风电弱送端直流工程电压稳定快速评估方法[J].可再生能源,2018,36(7):1062-1066.SHAO Baozhu, ZHANG Wenchao, LI Jiajue, et al.Voltage stability and fast evaluation method for large scale wind farm weakly ended dc project based on short circuit capacity[J]. Renewable Energy Resources,2018, 36(7):1062-1066.
- [15]郝博可,赵洪峰,程宽,等.特高压交直流混联输电及稳定运行综述[J].东北电力技术,2019,40(7):5-7.HAO Boke, ZHAO Hongfeng, CHENG Kuan, et al.Overview of UHV AC/DC hybrid transmission and Its stable operation[J]. Northeast Electric Power Technology, 2019, 40(7):5-7.
- [16]凌卫家,孙维真,叶琳,等.浙江交直流混联电网特性分析及运行控制[J].浙江电力,2016,35(9):8-14.LING Weijia, SUN Weizhen, YE Lin, et al. Characteristics analysis and operation control of Zhejiang hybrid AC/DC power grid[J]. Zhejiang Electric Power,2016, 35(9):8-14.
- 风火电源打捆
- 特高压
- 功角稳定
- 直流闭锁
- 输电能力
- 新能源
- 消纳
wind-thermal-bundled - UHV
- power angle stability
- DC blocking
- transmission capacity
- new energy
- consumption