摘要(Abstract):

为适应电网一次调频性能考核,火电机组普遍对原有的一次调频功能进行了优化,针对“反向调节闭锁”“快动缓回”“加速冲量响应”几种典型的策略,分析其优、缺点,提出了兼顾机组稳定性的火电机组的一次调频优化策略,同时针对供热机组在尖寒期机组出力超限、响应电网低频能力下降问题,提出了采用热网储能来响应机组一次调频负荷需求的控制策略。优化后的一次调频优化策略,在提升一次调频性能的同时,能够最大程度降低对机组运行稳定性带来的不利影响。
In order to adapt to the primary frequency compensation performance assessment of power grid, thermal power units generally optimize the original primary frequency compensation function. Aiming at several typical optimization strategies such as reverse regulation locking, fast moving and delay return and accelerate impulse response, on the basis of their advantages and disadvantages, this paper puts forward the primary frequency compensation optimization strategy of thermal power units taking into account the stability of units. At the same time, in view of the phenomenon that the output of heating units exceeds the limit and responds to the decline of low frequency capacity of power grid in severe cold season, the control strategy of using energy storage in heat supply network to respond to the demand of primary frequency compensation load of unit is proposed. The new primary frequency compensation optimization strategy improves the primary frequency compensation performance of the unit, and at the same time minimizes the adverse impact on the stability of the unit.

关键词(KeyWords): 一次调频;小频差;优化策略;一次调频性能考核;供热机组
primary frequency compensation;small frequency deviation;optimization strategy;primary frequency compensation performance assessment;heating unit

Abstract:

Keywords:

基金项目(Foundation): 内蒙古电力(集团)有限责任公司科技项目“基于电网一次调频考核下全网安全评估与优化策略的研究”(2022-26)

作者(Author): 殷建华,张国斌,贾斌,于海存
YIN Jianhua,ZHANG Guobin,JIA Bin,YU Haicun

参考文献(References):

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享